AH0608 OIL COOLER

AH0608T-CA OIL COOLER

AH0608T-CA OIL COOLER,AH0608 OIL COOLER, AH0608-CA-60L/MIN AC230V,AC110V,DC24V.DC12V

AF/AH Series Industrial Machine Plate-Fin AIR OIL Heat Exchanger(AIR OIL COOLER)

AH0608-CA,AH0608TL-CA-60L,AH0607T-CA-40L,AF0510T-CA-10L,AF1025T-CA-25L,AL404T-CA-10L,AL608T-CA-10L,AL609T-CA-10L,AW0607T-CA-20L,AH0608T-CA-60L,AH0609T-CA-90L,AH1012T-CA-100L,AH1417T-CA-150L,AH1470T-CA-200L,AH1490T-CA-250L,AH1680T-CA-300L,AH2431T-CA-450L,,AH3818T-CA-600L,AH3-2583T-CA,AH1890T-CA,SQ1015T-CA,SQ1015T-CA,ECO-07,FR-02,FR-03,FR-04,FR-05,LOC-004,LOC-007,LOC-011,LOC-016,LOC-023,AHD-20-CA,AHJ-20-CA,AHD-50-CA,LOC-033,LOC2-033,AH1215-CA

AH0608T Oil Cooler  Characteristics:

AF/AH series of aluminium wind condenser is made from aluminium which is light weight and has high resistant against vibration and high efficiency in heat exchange .In terms of the structure, a fin is placed inside the heat pipe to bring the heat away by air. As a result, a profit can be earned from the low cost and high efficency of cooling effect can be obtained.Thus, it will be an effective heat exchanger in the market..As the plate – fin aluminum high-pressure air cooler has the following advantages, it is being  widely used  among the world, especially in Europe.

 

AH0608T Oil Cooler  parameter:

Cooler element,plate-fin heat exchanger,in high resistance aluminum alloy,carried out through a construction process,which used a special system of braze welding.
Test pressure : 30Bar.
Operating pressure : 20Bar.
Max operating temperature : 120℃
To preserve the heat exchanger, when installed on the return line of the system,a by pass valve should always be mounted in parallel to the exchanger in order to avoid excessive pressure surges.

AH0608T-CA*

Description:
Product model:AH0608T-CA*
Brand:ORCAER/COOLPLUS
Nozzle diameter:3/4″(PT)
Nominal pressure:20 Bar
Outline size:305*200*115  mm
Weight:4.2kg

AH0608T-CA

Model Flow range Standard voltage Frequency Power Electric current Speed Air volumn Protection grade Noise Authentication Remarks
L/min V Hz W A R.P.M m³/h IP dB(A) Temperature protection
AH0608T-CA1 3-60 Single-phase 115 50/60 45/37 0.6/0.5 2850/3450 457/553 54 42/48 CE
AH0608T-CA2 Single-phase 230 50/60 45/37 0.27/0.23 2850/3450 457/553 54 42/48 CE
AH0608T-CA3 Single-phase 380 50/60 30/25 0.16/0.14 2850/3450 457/553 54 42/48 CE

AH0608T-CD

Model Flow range Standard voltage Frequency Power Electric current Speed Air volumn Protection grade Noise Authentication Remarks
L/min V Hz W A R.P.M m³/h IP dB(A) Soft start and waterproof

Brushless and locked rotor protection

AH0608T-CD1 3-60 CD 12 12 1.0 2700 445 68 40 CE
AH0608T-CD2 CD 24 12 0.5 2700 445 68 40 CE